当前位置: 移动技术网 > 科技>操作系统>Linux > (Nagios)-check_hpasm[HP]

(Nagios)-check_hpasm[HP]

2018年02月12日  | 移动技术网科技  | 我要评论

mp3电子书免费下载,兽魔狐仙,金盾国际保镖

Nagios Check_hp HP
2014年11月18日
下午 08:49
 
 
  [root@nagios ~]# tar zxvf check_hp_bladechassis-1.0.1.tar.gz
  [root@nagios check_hp_bladechassis-1.0.1]# ./check_hp_bladechassis -H xxx.xxx.xxx.xxx
  SNMP ERROR: Can't determine model name
  [root@nagios check_hp_bladechassis-1.0.1]# snmpwalk -Os -c public -v 1 xxx.xxx.xxx
  [root@nagios libexec]# ./check_hpasm -H xxx.xxx.xxx -C public
  CRITICAL - snmpwalk returns no product name (cpqsinfo-mib), wrong device
windows端安装ilo驱动 (必须),先安装SNMPAgent(cp024529_log_th.exe  cp024617_ilo_th.exe  cp022559_hp_agents_w2008.exe)
  [root@nagios libexec]# ./check_hpasm -H xxx.xxx.xxx
  OK - System: 'proliant dl380p gen8', S/N: '*******', ROM: 'P70 03/01/2013', hardware working fine, da: 2 logical drives, 16 physical drives
Redhat系统下安装agent
  [root@localhost ~]# rpm -ivh hpacucli-9.40-12.0.x86_64.rpm(不必须)
  rpm -ivh hp-health-9.50-1631.33.rhel5.x86_64.rpm(必须)
  rpm -ivh hp-snmp-agents-9.50-2564.34.rhel5.x86_64.rpm(必须)
  /etc/init.d/hp-snmp-agents start
  需要配置snmp
  /sbin/hpsnmpconfig
  /etc/init.d/hp-health restart
  /etc/init.d/hp-asrd restart
  /etc/init.d/hp-snmp-agents restart
其他Server访问不了
  [root@nagios libexec]# ./check_hpasm -H xxx.xxx.xxx
  CRITICAL - snmpwalk returns no product name (cpqsinfo-mib), wrong device
但本地能检查出数据,所以是snmp配置有误。
  [root@localhost plugins-scripts]# ./check_hpasm
  OK - System: 'proliant dl380p gen8', S/N: '*******', ROM: 'P70 03/01/2013', hardware working fine
Linux下配置snmp(可从其他机台copy过来)
  [root@localhost plugins-scripts]# vim /etc/snmp/snmpd.conf
  #add (网上参考) <http://javatechnology.iteye.com/blog/768001>
  #       sec.name  source          community
  com2sec notConfigUser  [監控主機]      public
 
  .1表示所有设备信息
  view    systemview    included   .1
  修改process checks(去掉注释)
  # proc mountd
  # proc ntalkd 4
  # proc sendmail 10 1
  修改Executables/scripts配置(去掉注释)
  #exec echotest /bin/echo hello world
  修改disk checks配置(去掉注释)
  #disk / 10000
  修改load average checks配置(去掉注释)
  #load 12 14 14
  [root@localhost plugins-scripts]# service snmpd restart
  其他Server获取信息ok
  [root@nagios libexec]# ./check_hpasm -H xxx.xxx.xxx
  OK - System: 'proliant dl380p gen8', S/N: '*******', ROM: 'P70 03/01/2013', hardware working fine, da: 1 logical drives, 14 physical drives
 
  注意:proliant dl380 gen9
  rpm -ivh hp-health-10.10-1710.30.rhel6.x86_64.rpm
  rpm -ihv hp-snmp-agents-10.10-2732.25.rhel6.x86_64.rpm
 
cp029394_ilo_Interface.exe
cp029429_ilo_Management.exe 
cp030048_Agent.exe
 
 
 
 
 
 
 
 
 
 

如对本文有疑问,请在下面进行留言讨论,广大热心网友会与你互动!! 点击进行留言回复